Click here for drawings, CAD, and construction instructions
* Building side and ground side fixed mounts are sold separately.
*The H system is shown as a representative example.
Workability | Working space | Cost |
---|---|---|
△ | △ | △ |
・A system in which the caster trolley operates directly on the floor.
・It is the most suitable system for large-diameter systems.
・Operating temperature: 300°C or less
・Working pressure: 0.98Mpa
・Tube material: SUS316L
Japan Water Works Association certified product.
・Operating temperature: 40℃ or less
・Working pressure: S1 type 0.98Mpa, S2 type 1.96Mpa
・Tube material: SUS316L
Fire and Disaster Management Agency Notification No. 31 certified product (20A and 25A are compliant products)
・Operating temperature: 300°C or less
・Working pressure: 0.98Mpa
・Tube material: SUS316L
・Operating temperature: 100°C or less
・Working pressure: 0.98Mpa
・Tube material: SUS304
・Flange material: SS400 (electrogalvanized)
Compliant with Fire Danger No. 20.
・Operating temperature: room temperature
・Working pressure: 0.98Mpa or less
Piping call | standard Elbow length | Seismic isolation amount | |||
---|---|---|---|---|---|
500mm | 600mm | 700mm | 800mm | ||
Flexible cable length | Flexible cable length | Flexible cable length | Flexible cable length | ||
20A | 330 | 1100 | 1200 | 1400 | 1600 |
25A | 330 | 1100 | 1200 | 1400 | 1600 |
32A | 330 | 1100 | 1200 | 1400 | 1600 |
40A | 330 | 1100 | 1200 | 1400 | 1600 |
50A | 330 | 1100 | 1200 | 1400 | 1600 |
65A | 280 | 1200 | 1300 | 1500 | 1700 |
80A | 300 | 1200 | 1300 | 1500 | 1700 |
100A | 340 | 1300 | 1400 | 1600 | 1800 |
125A | 380 | 1400 | 1500 | 1700 | 1900 |
150A | 410 | 1500 | 1600 | 1800 | 2000 |
Piping call | SUS 10K S1 type | SUS 20K S2 type | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
standard Elbow length | Seismic isolation amount | standard Elbow length | Seismic isolation amount | |||||||
500mm | 600mm | 700mm | 800mm | 500mm | 600mm | 700mm | 800mm | |||
Flexible cable length | Flexible cable length | Flexible cable length | Flexible cable length | Flexible cable length | Flexible cable length | Flexible cable length | Flexible cable length | |||
20A | 330 | 1100 | 1200 | 1400 | 1600 | 330 | 1200 | 1300 | 1500 | 1700 |
25A | 330 | 1100 | 1200 | 1400 | 1600 | 330 | 1200 | 1300 | 1500 | 1700 |
32A | 330 | 1100 | 1200 | 1400 | 1600 | 330 | 1200 | 1300 | 1500 | 1700 |
40A | 330 | 1100 | 1200 | 1400 | 1600 | 330 | 1200 | 1300 | 1500 | 1700 |
50A | 330 | 1100 | 1200 | 1400 | 1600 | 330 | 1200 | 1300 | 1500 | 1700 |
65A | 280 | 1200 | 1300 | 1500 | 1700 | 280 | 1300 | 1400 | 1600 | 1800 |
80A | 300 | 1200 | 1300 | 1500 | 1700 | 300 | 1400 | 1500 | 1700 | 1900 |
100A | 340 | 1300 | 1400 | 1600 | 1800 | 340 | 1500 | 1700 | 1900 | *2100 |
125A | 380 | 1400 | 1500 | 1700 | 1900 | 380 | 1700 | 1900 | *2100 | *2300 |
150A | 410 | 1500 | 1600 | 1800 | 2000 | 410 | 1900 | 2000 | *2200 | *2400 |
200A | 490 | 1800 | 1900 | 2200 | 2400 | 490 | 2000 | *2200 | *2400 | ー |
250A | 620 | 1900 | 2000 | 2300 | 2500 | ー | ー | ー | ー | ー |
The 20K S2 type flexible cable becomes a compliant product if the flexible cable length exceeds 2000mm. (See *)
Piping call | standard Elbow length | Seismic isolation amount | |||
---|---|---|---|---|---|
500mm | 600mm | 700mm | 800mm | ||
Flexible cable length | Flexible cable length | Flexible cable length | Flexible cable length | ||
20A | 330 | 1100 | 1200 | 1400 | 1600 |
25A | 330 | 1100 | 1200 | 1400 | 1600 |
32A | 330 | 1100 | 1200 | 1400 | 1600 |
40A | 330 | 1100 | 1200 | 1400 | 1600 |
50A | 330 | 1100 | 1200 | 1400 | 1600 |
65A | 280 | 1200 | 1300 | 1500 | 1700 |
80A | 300 | 1200 | 1300 | 1500 | 1700 |
100A | 340 | 1300 | 1400 | 1600 | 1800 |
125A | 380 | 1400 | 1500 | 1700 | 1900 |
150A | 410 | 1500 | 1600 | 1800 | 2000 |
200A | 490 | 1800 | 1900 | 2200 | - |
250A | 620 | 1900 | 2000 | 2300 | - |
300A | 690 | 2100 | 2200 | 2400 | - |
Piping call | standard Elbow length | Seismic isolation amount | |||
---|---|---|---|---|---|
500mm | 600mm | 700mm | 800mm | ||
Flexible cable length | Flexible cable length | Flexible cable length | Flexible cable length | ||
20A | 330 | 1200 | 1400 | 1600 | 1700 |
25A | 330 | 1200 | 1400 | 1600 | 1700 |
32A | 330 | 1200 | 1400 | 1600 | 1700 |
40A | 330 | 1200 | 1400 | 1600 | 1700 |
50A | 330 | 1300 | 1400 | 1700 | 1700 |
65A | 280 | 1400 | 1500 | 1700 | 1800 |
80A | 300 | 1500 | 1700 | 1800 | 1900 |
100A | 340 | 1600 | 1800 | 1900 | 2200 |
125A | 380 | 1800 | 1900 | 2200 | 2400 |
150A | 410 | 1900 | 2100 | 2300 | 2500 |
200A | 490 | 2200 | 2300 | 2500 | - |
250A | 620 | 2400 | 2500 | 2700 | - |
Piping call | standard Elbow length | Seismic isolation amount | |||
---|---|---|---|---|---|
500mm | 600mm | 700mm | 800mm | ||
Flexible cable length | Flexible cable length | Flexible cable length | Flexible cable length | ||
15A | 330 | 1100 | 1200 | 1400 | 1600 |
20A | 330 | 1100 | 1200 | 1400 | 1600 |
25A | 330 | 1100 | 1200 | 1400 | 1600 |
32A | 330 | 1100 | 1200 | 1400 | 1600 |
40A | 330 | 1100 | 1200 | 1400 | 1600 |
50A | 330 | 1100 | 1200 | 1400 | 1600 |
65A | 280 | 1200 | 1300 | 1500 | 1700 |
80A | 300 | 1200 | 1300 | 1500 | 1700 |
100A | 340 | 1300 | 1400 | 1600 | 1800 |
125A | 380 | 1400 | 1500 | 1700 | 1900 |
150A | 410 | 1500 | 1600 | 1800 | 2000 |
All rights reserved, © Copyright Kurashiki Kako Co., Ltd.
Feel free to contact us for a quote or inquiry