No | Seismic isolation amount (mm) |
Usage | system | Material | Maximum use temperature |
Maximum use pressure |
standard list |
CAD (2D) |
CAD (3D) | Construction instructions |
|||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
IFCMore | DWG | Rebro | |||||||||||||
1 | 500 | Water supply/Clean water | MF-V: 1 vertical type | rubber high pressure | 40℃ | 0.98MPa | drawing | DXF | ZIP | ||||||
2 | 500 | Water supply/Clean water | MF-V: 1 vertical type | SUS | 70℃ | 0.98MPa | drawing | DXF | ZIP | ||||||
3 | 500 | Water supply/Clean water | MF-S: Horizontal single type | SUS | 70℃ | 0.98MPa | drawing | DXF | ZIP | ||||||
4 | 500 | Water supply/Clean water | H: Hanging type | rubber high pressure | 40℃ | 0.98MPa | drawing | DXF | ZIP | ||||||
5 | 500 | Water supply/Clean water | P: Pulley hanging type | rubber high pressure | 40℃ | 0.98MPa | drawing | DXF | ZIP | ||||||
6 | 500 | Water supply/Clean water | C: Caster type | rubber high pressure | 40℃ | 0.98MPa | drawing | DXF | ZIP | ||||||
7 | 500 | Water supply/Clean water | H: Hanging type | SUS | 90℃ | 0.98MPa | drawing | DXF | ZIP | ||||||
8 | 500 | Water supply/Clean water | P: Pulley hanging type | SUS | 90℃ | 0.98MPa | drawing | DXF | ZIP | ||||||
9 | 500 | Water supply/Clean water | C: Caster type | SUS | 90℃ | 0.98MPa | drawing | DXF | ZIP | ||||||
10 | 500 | Water supply/Clean water | MB-MK: Ball joint vertical type | FCD, etc. | 60℃ | 2.0 MPa | drawing | DXF | ZIP | ||||||
11 | 500 | Hot water supply | MF-V: 1 vertical type | SUS | 90℃ | 0.98MPa | drawing | DXF | ZIP | ||||||
12 | 500 | Hot water supply | MF-S: Horizontal single type | SUS | 90℃ | 0.98MPa | drawing | DXF | ZIP | ||||||
13 | 500 | Hot water supply | H: Hanging type | SUS | 90℃ | 0.98MPa | drawing | DXF | ZIP | ||||||
14 | 500 | Hot water supply | P: Pulley hanging type | SUS | 90℃ | 0.98MPa | drawing | DXF | ZIP | ||||||
15 | 500 | Hot water supply | C: Caster type | SUS | 90℃ | 0.98MPa | drawing | DXF | ZIP | ||||||
16 | 500 | Drainage/Sewage | MF-V: 1 vertical type | rubber low pressure | 70℃ | 0.29 MPa | drawing | DXF | ZIP | ||||||
17 | 500 | Drainage/Sewage | MF-S: Horizontal single type | rubber low pressure | 70℃ | 0.29 MPa | drawing | DXF | ZIP | ||||||
18 | 500 | Drainage/Sewage | MB-HY: Ball joint horizontal type | FCD, etc. | 60℃ | 0.3MPa | drawing | DXF | ZIP | ||||||
19 | 500 | Drainage/Sewage | MB-HY: Ball joint horizontal type | VPs | 40℃ | Atmospheric pressure | drawing | DXF | ZIP | ||||||
20 | 500 | Extinguishing (10K) | MF-V: 1 vertical type | SUS | 40℃ | 0.98MPa | drawing | DXF | ZIP | ||||||
21 | 500 | Extinguishing (10K) | H: Hanging type | SUS | 40℃ | 0.98MPa | drawing | DXF | ZIP | ||||||
22 | 500 | Extinguishing (10K) | P: Pulley hanging type | SUS | 40℃ | 0.98MPa | drawing | DXF | ZIP | ||||||
23 | 500 | Extinguishing (10K) | C: Caster type | SUS | 40℃ | 0.98MPa | drawing | DXF | ZIP | ||||||
24 | 500 | Extinguishing (10K) | MB-MK: Ball joint vertical type | FCD, etc. | 60℃ | 1.0 MPa | drawing | DXF | ZIP | ||||||
25 | 500 | Fire extinguishing (20K), connected water supply | H: Hanging type | SUS | 40℃ | 1.96 MPa | drawing | DXF | ZIP | ||||||
26 | 500 | Fire extinguishing (20K), connected water supply | P: Pulley hanging type | SUS | 40℃ | 1.96 MPa | drawing | DXF | ZIP | ||||||
27 | 500 | Fire extinguishing (20K), connected water supply | C: Caster type | SUS | 40℃ | 1.96 MPa | drawing | DXF | ZIP | ||||||
28 | 500 | Fire extinguishing (16K), connected water supply | MB-MK: Ball joint vertical type | FCD, etc. | 60℃ | 1.6 MPa | drawing | DXF | ZIP | ||||||
29 | 500 | Fire extinguishing (20K), connected water supply | MB-MK: Ball joint vertical type | FCD, etc. | 60℃ | 2.0 MPa | drawing | DXF | ZIP | ||||||
30 | 500 | Cold water, hot water, hot and cold water, cooling water | MF-V: 1 vertical type | rubber high pressure | 70℃ | 0.98MPa | drawing | DXF | ZIP | ||||||
31 | 500 | Cold water, hot water, hot and cold water, cooling water | H: Hanging type | rubber high pressure | 70℃ | 0.98MPa | drawing | DXF | ZIP | ||||||
32 | 500 | Cold water, hot water, hot and cold water, cooling water | P: Pulley hanging type | rubber high pressure | 70℃ | 0.98MPa | drawing | DXF | ZIP | ||||||
33 | 500 | Cold water, hot water, hot and cold water, cooling water | C: Caster type | rubber high pressure | 70℃ | 0.98MPa | drawing | DXF | ZIP | ||||||
34 | 500 | Cold water, hot water, hot and cold water, cooling water | H: Hanging type | SUS | 90℃ | 0.98MPa | drawing | DXF | ZIP | ||||||
35 | 500 | Cold water, hot water, hot and cold water, cooling water | P: Pulley hanging type | SUS | 90℃ | 0.98MPa | drawing | DXF | ZIP | ||||||
36 | 500 | Cold water, hot water, hot and cold water, cooling water | C: Caster type | SUS | 90℃ | 0.98MPa | drawing | DXF | ZIP | ||||||
37 | 500 | Cold water, hot water, hot and cold water, cooling water | MB-MK: Ball joint vertical type | FCD, etc. | 60℃ | 1.0 MPa | drawing | DXF | ZIP | ||||||
38 | 500 | Oil | H: Hanging type | SUS | 100℃ | 0.98MPa | drawing | DXF | ZIP | ||||||
39 | 500 | Oil | P: Pulley hanging type | SUS | 100℃ | 0.98MPa | drawing | DXF | ZIP | ||||||
40 | 500 | Oil | C: Caster type | SUS | 100℃ | 0.98MPa | drawing | DXF | ZIP | ||||||
41 | 500 | Oil | MB-MK: Ball joint vertical type | FCD, etc. | 60℃ | 1.0 MPa | drawing | DXF | ZIP | ||||||
42 | 500 | Oil | MB-HY: Ball joint horizontal type | FCD, etc. | 60℃ | 1.0 MPa | drawing | DXF | ZIP | ||||||
43 | 500 | Vapor | MF-V: 1 vertical type | SUS | 160℃ | 0.8MPa | drawing | DXF | ZIP | ||||||
44 | 500 | Vapor | H: Hanging type | SUS | 300℃ | 0.98MPa | drawing | DXF | ZIP | ||||||
45 | 500 | Vapor | P: Pulley hanging type | SUS | 300℃ | 0.98MPa | drawing | DXF | ZIP | ||||||
46 | 500 | Vapor | C: Caster type | SUS | 300℃ | 0.98MPa | drawing | DXF | ZIP | ||||||
47 | 500 | Medical gas | H: Hanging type | SUS | At normal temperature | 0.98MPa | drawing | DXF | ZIP | ||||||
48 | 500 | Medical gas | P: Pulley hanging type | SUS | At normal temperature | 0.98MPa | drawing | DXF | ZIP | ||||||
49 | 500 | Medical gas | C: Caster type | SUS | At normal temperature | 0.98MPa | drawing | DXF | ZIP | ||||||
50 | 500 | Chemical solution/pure water | MF-V: 1 vertical type | PTFE | 150℃ | 0.98MPa | drawing | DXF | ZIP |
All rights reserved, © Copyright Kurashiki Kako Co., Ltd.